Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 678(2): 203-7, 2010 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-20888453

RESUMO

We have developed a novel method for the determination of iodate based on the carboxymethyl cellulose-capped CdS quantum dots (QDs). Factors affecting the iodate detection were investigated, and the optimum conditions were determined. Under the optimum conditions, the relative fluorescence intensity of CdS quantum dots was linearly proportional to IO(3)(-) over a concentration range from 1.0 × 10(-8) to 1.0 × 10(-5) mol L(-1) with a correlation coefficient of 0.9987 and a detection limit of 6.0 nmol L(-1). Iodide, being oxidized by bromine to form iodate, was detected indirectly. The method was successfully applied to the determination of iodate and total amount of iodine in table salt samples. The related mechanism was also discussed.


Assuntos
Compostos de Cádmio , Corantes Fluorescentes , Iodatos/análise , Pontos Quânticos , Cloreto de Sódio na Dieta/análise , Sulfetos , Compostos de Cádmio/química , Carboximetilcelulose Sódica/química , Iodo/análise , Limite de Detecção , Cloreto de Sódio na Dieta/normas , Espectrometria de Fluorescência/métodos , Sulfetos/química
2.
Anal Chim Acta ; 604(2): 170-6, 2007 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-17996539

RESUMO

We report the synthesis of a novel looped enzyme-polyamidoamine nanocomposite with high enzyme loading density and long-term retention of bioactivity. The horseradish peroxidase (HRP) is first immobilized on fourth-grade (G4) poly(amidoamine) (PAMAM) dendrimer to form relatively a small enzyme-PAMAM composite, which is allowed to grow up into a larger one. The looped horseradish peroxidase-polyamidoamine (HRP-PAMAM) nanohybrid was characterized by TEM. The material obtained shows promising features as applied to the fabrication of high sensitive and long lifetime biosensors. In the presence of the hydroquinone mediator in the solution, the immobilized HRP exhibited excellent electro-catalytical response to H2O2. Under the optimal conditions, the resulting biosensor showed a linear response to H2O2 over a concentration range from 3.1x10(-6) to 2.0x10(-3) mol L(-1) with a sensitivity of 0.36 A L mol(-1) cm(-2) and a detection limit of 8.0x10(-7) mol L(-1). The sensitivity of the sensor response maintained over 70% of the original over 10 weeks. The catalytic activity of the looped enzyme-PAMAM nanohybrid form of HRP enzyme was obviously stabilized. As an extension, bienzyme sensor modified with glucose oxidase and HRP enzymatic PAMAM nanocomposites was constructed. The sensor exhibited improved performance and can be applied to the detection of glucose in real samples.


Assuntos
Técnicas Biossensoriais , Dendrímeros/química , Enzimas Imobilizadas/química , Peroxidase do Rábano Silvestre/química , Nanoestruturas , Poliaminas/química , Eletroquímica , Microscopia Eletrônica de Transmissão
3.
Anal Sci ; 22(3): 393-7, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16733310

RESUMO

A cobalt(II) tetrakisphenylporphyrin (Co(II)TPP) film modified glassy carbon electrode (Co(II)TPP-GCE) was prepared by just coating Co(II)TPP solution on the surface of the electrode. It can be used for the simultaneous determination of ascorbic acid and uric acid. The anodic peaks of AA and UA can be separated well. Owing to the strongly hydrophobic property of porphyrin, the modified electrode has good stability and long life. The linear range for UA and AA were 2.0 x 10(-6)-1.0 x 10(-4) M and 9.0 x 10(-6)-2.0 x 10(-3) M with detection limits of 5.0 x 10(-7) and 5.0 x 10(-6) M, respectively. Furthermore, metalloporphyrins of other kinds were also used to construct modified electrodes. Their performances were inferior compared with that of the Co(II)TPP modified electrode.


Assuntos
Ácido Ascórbico/análise , Carbono/química , Cobalto/química , Metaloporfirinas/química , Ácido Úrico/análise , Ácido Ascórbico/urina , Eletroquímica/instrumentação , Eletroquímica/métodos , Eletrodos , Humanos , Concentração de Íons de Hidrogênio , Metais/química , Reprodutibilidade dos Testes , Ácido Úrico/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...